Recommended basic settings for Pakistan home energy storage systems (Solar → Battery → Grid priority logic).

LED Indicators & Status Descriptions
①AC Indicator (Green)
- On: GRIDpower normal, inverter operating on GRID
- Flashing: GRIDpower normal, unit not operating on GRID
- Off: GRIDpower abnormal.
②Inverter Indicator (Yellow)
- On: Output powered by batteries or PV in battery mode.
- Off: Other operating statuses.
③Charging Indicator (Yellow)
- On: Battery under float charging.
- Flashing: Battery under constant-voltage charging.
- Off: Other operating statuses.
④Fault Indicator (Red)
- On: Inverter malfunction.
- Flashing: Inverter warning alarm triggered.
- Off: Inverter operating normally.

1, How to Enter Setting Mode
- Press and hold the ENTER button for 2 seconds.
- Use UP / DOWN buttons to select the setting item.
- Press ENTER to confirm.
- Press ESC to exit the menu.
2. Recommended Basic Settings
| Function | Program No. | Recommended Setting | Description |
| Output Priority | 03 | SBU / PGB | Solar first, then Battery, then Grid |
| BMS Communication Function | 44 | PLY(Hua Power Battery) | OFF default
CVT: CVTE protocol (485) PYL: PYLON protocol (485 and CAN)-HUAPOWER Battery GRO: GROWATT protocol (485 and CAN) VOL: VOLTRONIC protocol (485) IRO: China Tower protocol (485) PAR: PACE RTU protocol (485) |
| Charging Priority | 05 | PNG | Solar charging first, grid assists when needed |
| Battery Type | 17 | FEL / Lithium | Select lithium battery mode |
| BMS Communication | 44 | ON | Enable lithium battery communication |
| Grid Charging Current | 06 | 20A ~ 40A | Recommended for home systems |
| Maximum Charging Current | 07 | 80A ~ 120A | Depends on battery capacity |
| Low SOC to Grid | 48 | 10% | Switch to grid when battery is low |
| High SOC to Battery | 47 | 90% | Return to battery mode automatically |
Program NO 06 reference:
| Battery capacity | Suggestion Current |
| 100Ah | 20A |
| 200Ah | 40A |
| 300Ah | 60A |
Program NO 07 reference:
| Battery capacity | Suggestion Current |
| 100Ah | 50A |
| 200Ah | 100A |
| 300Ah | 120A |
3. Recommended Working Logic
- Solar power supplies the load first.
- If solar power is not enough, battery power will support the load.
- If both solar and battery are insufficient, the inverter switches to grid power automatically.
4. Important Notes
- Always enable BMS communication for lithium batteries.
- Do not select AGM mode for lithium batteries.
- Avoid setting charging current too high to protect battery life.
- PNG mode is the most stable setting for Pakistan market applications.
5. Quick Explanation for Customers
“The system uses solar power first, then battery power, and only uses grid power when necessary. This saves electricity cost and ensures stable backup power.”